How AC service are not cold in their own homes

 How AC service are not cold in their own homes
 How AC service are not cold in their own homes

How will I fix the air conditioner does not cool or less cold in your house? My tutorial this time specifically for AC branded SHARP , AC sharp because this model is easier to open when compared with other brands ( does not require special skills ) from daring to try it can. and the problem is not cold because the gross indoor.

Any cause of AC is not cold ? there are many contributing factors like because DIRTY . can in indoor or outdoor.

1. Make sure the remote ac are at the correct setting . for example in the COOL mode set but you chose a temperature of 30 degrees of course AC could not cool , or you pressed the wrong course FAN mode AC could not cool . which really is a select set COOL mode (symbol in the remote such as the sun ) and put it at a temperature below 25 degrees ( depending on the outside temperature and the room you need ) small bushes will be getting colder .

2. then turn on the AC and feel the wind blowing ! if the ac dirty hembusanya be slow and his voice can not be smoothly anginya also usually no noise kayak mbrebet GTU . You can see a video tutorial on how to clean

3. AC on half an hour after you try to look at the water pembuanagn that are behind its indoor wall ! if there is water out and smoothly means gas freon in ac you most likely still be normal ( to determine the exact measuring devices must use manifold )

4. The next check is in the out door, the wind that came out to be hot and hembusanya too fast , the higher the ac pk will be higher the anginya gusts . if the out door dirty then blowing anginya not tight . This will cause the compressor works of life and death because of overload is too hot . try to wash by spraying water on the condenser ( the pipe through which the wind grating ) and not sprayed on the cover body .

5. after the spray you have to feel the difference the wind of before in the spray . if it makes no difference , it means there is damage to the capacitor fan , usually micro farrad its value decreases causing rotation ( rpm ) of the fan decreases . you can change it by opening the cover and a small black box shaped object with the literature of 1.5 mf .

6. but if the effluent does not come out at all it could be because :
  • Soak compressor capacitor that causes the compressor does not spin
  • No freon leak could on its own connection or unit
  • or the compressor itself was broken , on winding or mechanicals
  • The indoor module does not give orders that are not flame out door
to point 6 in keahliah need special and adequate equipment , I 'll peel it in the next article .
,